2004 CDF E-Log -- Eve shift. Thu Feb 26, 2004 |
| SciCo |
DAQ Ace |
Monitoring Ace |
CO |
(Operations Manager) |
| Robert Harris |
Simon Sabik |
Chris Marino |
Josh Tuttle |
JJ Schmidt |
Start of Shift Notes:  Currently no beam following a quench. The stack is at 186 mA and there is no plan yet from
MCR. Work ongoing on the calorimeter electronics, the silicon, and a PMT spike test run is
planned.
Thu Feb 26 16:07:12
Run 179400
Terminated at 2004.02.26 16:07:04 - RunControl
Thu Feb 26 16:08:02
Run 179400
TERMINATE: to take SMX calib - Simon x2080
Thu Feb 26 16:12:32
Run 179401
ACTIVATE: SMX QIE calibration - Simon x2080
Thu Feb 26 16:14:16
Run 179401
TERMINATE: SMX QIE calibration - Simon x2080
Thu Feb 26 16:16:25
Run 179402
ACTIVATE: XTRP - 2TT - firmware default verification run - Christopher 2080
Thu Feb 26 16:24:09
Run 179403
ACTIVATE: CAL QIE calibration - Simon x2080
Thu Feb 26 16:24:44
Run 179403
TERMINATE: CAL QIE calibration - Simon x2080
-- Thu Feb 26 16:27:31 comment by...Simon -- (MLE) b0ccal08:Readout_Calib:4:23:59 PM->ADMEM=17 QIE=16 Fail 14: Sigma(off) big
(2.4797723) (0) (2)
(MLE) b0ccal02:Readout_Calib:4:24:00 PM->ADMEM=18 QIE=9 Fail 14: Sigma(off) big (2.0514584)
(2) (0)
(MLE) b0pcal07:Readout_Calib:4:24:03 PM->ADMEM=15 QIE=17 Fail 14: Sigma(off) big (1.1116625)
(1) (4)
b0pcal07) QIE calib: slot 15, qie 17:Fail 14: Sigma(off) big , val 01.1117, cap 1, rng4.
(b0pcal07) QIE calib: slot 15, qie 19:Fail 14: Sigma(off) big , val 01.2577, cap 0, rng3.
(b0pcal07) QIE calib: slot 17, qie 17:Fail 14: Sigma(off) big , val 01.0082, cap 1, rng4.
(b0pcal07) QIE calib: slot 17, qie 19:Fail 14: Sigma(off) big , val 01.4368, cap 0, rng2.
(b0pcal07) QIE calib: slot 19, qie 17:Fail 14: Sigma(off) big , val 01.0934, cap 0, rng4.
(b0pcal07) QIE calib: slot 19, qie 18:Fail 14: Sigma(off) big , val 01.1566, cap 0, rng6.
(b0pcal07) QIE calib: slot 19, qie 19:Fail 14: Sigma(off) big , val 01.0740, cap 0, rng4.
(b0pcal07) QIE calib: slot 21, qie 17:Fail 14: Sigma(off) big , val 01.1054, cap 0, rng4.
(b0pcal07) QIE calib: slot 21, qie 18:Fail 14: Sigma(off) big , val 01.5145, cap 0, rng4.
(b0pcal07) QIE calib: slot 21, qie 19:Fail 14: Sigma(off) big , val 01.0438, cap 2, rng2.
(b0pcal07) QIE calib: slot 14, qie 16:Fail 14: Sigma(off) big , val 01.5082, cap 0, rng4.
(b0pcal07) QIE calib: slot 14, qie 17:Fail 14: Sigma(off) big , val 01.1139, cap 0, rng4.
(b0pcal07) QIE calib: slot 14, qie 18:Fail 14: Sigma(off) big , val 01.5649, cap 0, rng1.
(b0pcal07) QIE calib: slot 14, qie 19:Fail 14: Sigma(off) big , val 01.2442, cap 0, rng4.
(b0pcal07) QIE calib: slot 16, qie 17:Fail 14: Sigma(off) big , val 01.2456, cap 0, rng4.
(b0pcal07) QIE calib: slot 16, qie 18:Fail 14: Sigma(off) big , val 01.0235, cap 2, rng5.
(b0pcal07) QIE calib: slot 16, qie 19:Fail 14: Sigma(off) big , val 01.6007, cap 0, rng2.
(b0pcal07) QIE calib: slot 18, qie 16:Fail 14: Sigma(off) big , val 02.5810, cap 0, rng4.
(b0pcal07) QIE calib: slot 18, qie 17:Fail 14: Sigma(off) big , val 01.4587, cap 0, rng4.
(b0pcal07) QIE calib: slot 18, qie 18:Fail 14: Sigma(off) big , val 01.0342, cap 0, rng2.
(b0pcal07) QIE calib: slot 18, qie 19:Fail 14: Sigma(off) big , val 01.0195, cap 0, rng4.
(b0pcal07) QIE calib: slot 20, qie 16:Fail 14: Sigma(off) big , val 01.3313, cap 0, rng4.
(b0pcal07) QIE calib: slot 20, qie 18:Fail 14: Sigma(off) big , val 01.4297, cap 0, rng5.
(b0pcal07) QIE calib: slot 20, qie 19:Fail 14: Sigma(off) big , val 01.2511, cap 0, rng2.
Thu Feb 26 16:26:25
JJ reports that MCR says we will have 2-4 hours more of quiet time. - Robert Harris
Thu Feb 26 16:32:02


- josh
-- Thu Feb 26 16:34:57 comment by...josh -- powercycling East Plug seems to fix the PCAL11 problems in these smx calibrations
Thu Feb 26 16:35:28
Run 179405
ACTIVATE: XTRP - 2TT - firmware default verification run -- after powercycle - Christopher 2080
Thu Feb 26 16:37:18
Run 179406
Activated at 2004.02.26 16:37:05 - RunControl
Thu Feb 26 16:37:19
Takasumi Maruyama is working on the SVT crates for about an hour. - Robert Harris
Thu Feb 26 16:39:28
Run 179406
ACTIVATE: test spike run. - Simon x2080
Thu Feb 26 16:41:23
Run 179406
Terminated at 2004.02.26 16:41:04 - RunControl
Thu Feb 26 16:42:40
 | during CALQIE calibration new bad channel found (channel 1 in wedge 22W of PHA detector) |
- josh
-- Thu Feb 26 18:12:30 comment by...m mattson -- Channels 0 and 1 of the PHA are PIN diodes. These are not used during data taking. The pedestals for these channels will drift, if they have recently been biased (or is it unbiased?).
Thu Feb 26 16:43:26
Run 179407
Activated at 2004.02.26 16:43:12 - RunControl
Thu Feb 26 16:43:50
Run 179407
ACTIVATE: test spike run. - Simon x2080
Thu Feb 26 17:03:05
Run 179407
Terminated at 2004.02.26 17:02:57 - RunControl
Thu Feb 26 17:07:06
Silicon SRC work
I looked at some possible timing issues in the SRC for clocking in
the TAXI. This is trying to find the cause of the occasional HRRs
due to the SRC fatal error 'Too many L1A' and 'L2 without L1'.
Nothing conclusive was found. The timing seems OK.
Links in silicon elog for the results are
this entry
and the following entry. - Lester
Thu Feb 26 17:07:15
Run 179408
ACTIVATE: CAl QIE calib. - Simon x2080
Thu Feb 26 17:07:36
Run 179408
TERMINATE: end CAL QIE. - Simon x2080
Thu Feb 26 17:12:31
Run 179409
Activated at 2004.02.26 17:11:07 - RunControl
Thu Feb 26 17:12:32
Run 179409
ACTIVATE: Spike run to check if everything is okay and it is. rate ~53 Hz. - Simon x2080
Thu Feb 26 17:13:41
 | (RUN 179408) 2nd CALQIE calibration (rms of bad channel is down below 10; expert is in control room now and says shouldn't be a problem) |
- josh
-- Thu Feb 26 17:15:22 comment by...V Tiwari -- The noisy PHA 22W, ch 1 is a PIN diode channel. It is *not* used for data-taking.
Thu Feb 26 17:18:23
We checked that the spike killer is disabled for spike runs using charge injection. We have put everything back to normal and have verified this using CAL QIE and the standard spike run. - R J Tesarek, V Tiwari
Thu Feb 26 17:20:35
Run 179409
Terminated at 2004.02.26 17:20:28 - RunControl
Thu Feb 26 17:22:08
Run 179409
TERMINATE: spike run - Simon x2080
Thu Feb 26 17:39:02
Run 179410
ACTIVATE: Plug laser calibration. Both plugs normal. - Simon x2080
Thu Feb 26 17:46:47
Run 179410
TERMINATE: Plug laser calib. Both plugs normal. - Simon x2080
Thu Feb 26 17:48:33
Run 179411
ACTIVATE: Plug Calibration. BOTHPLUGS_MM_C. - Simon x2080
Thu Feb 26 17:52:24
Run 179411
TERMINATE: Plug Calibration. BOTHPLUGS_MM_C. - Simon x2080
Thu Feb 26 17:56:38
Run 179413
TERMINATE: Plug Calibration. BOTHPLUGS_MM. - Simon x2080
Thu Feb 26 17:56:39
Run 179413
ACTIVATE: Plug Calibration. BOTHPLUGS_MM_C. - Simon x2080
Thu Feb 26 18:04:30
JJ informs us that we should be taking cosmic ray runs.
Takasumi Maruyama is still working on the SVT crates and
David Clark is still working on the Silicon, so we begin the
cosmic ray running without these systems. - Robert Harris
Thu Feb 26 18:06:34
Run 179414
Activated at 2004.02.26 18:05:54 - RunControl
Thu Feb 26 18:06:40
Run 179414
ACTIVATE: COSMICS_NOSILICON_TAPE [12,391,403] - Simon x2080
-- Thu Feb 26 18:33:14 comment by...Simon -- SVT crates excluded.
Thu Feb 26 18:13:22
Run 179415
ACTIVATE: SVT Level-2 preselection test - maruyama
Thu Feb 26 18:16:43
David Clark finishes working on the silicon. - Robert Harris
Thu Feb 26 18:17:37
Run 179415
TERMINATE: Stopped run for SVT preselection. - maruyama
Thu Feb 26 18:32:52
Run 179414
Terminated at 2004.02.26 18:32:29 - RunControl
Thu Feb 26 18:32:53
Run 179414
TERMINATE: to include silicon - Simon x2080
Thu Feb 26 18:34:38
Takasumi Maruyama finishes work on the SVT crates. - Robert Harris
Thu Feb 26 18:38:28
Run 179416
Activated at 2004.02.26 18:37:40 - RunControl
Thu Feb 26 18:42:05
We tested new GB firmware to improve the L2 processing time
by 2-3 usec. (count #good tracks inside this board. then L2
can waste the less meaningful data using that count number).
The improved firmware itself looks fine, but we have trouble in
writing FRAM read/write related to VME crates. It seems that
we need one more iteration. (with sending email to Ops/dicuss it
at 8:00 meeting)
- Jahred and Taka (for SVT gruop)
Thu Feb 26 18:45:39
Run 179416
ACTIVATE: COSMICS SILICON_TAPE [12,391,403] - Simon x2080
Thu Feb 26 19:39:31
Rob Roser is trying to get hold of Jim Morgan, the Tevatron run coordinator, to understand whether the quench is understood and whether it is safe to run with the silicon in. If Jim calls we
should tell him to call Rob at his cell phone number 399-2609. - Robert Harris
Thu Feb 26 21:02:07
JJ says he is going to change some network connections on the 3rd floor of B0. - Robert Harris
Thu Feb 26 21:56:02
I just talked to Brent (Crew Chief) in MCR. They are having
problems with the last bit of cooldown of A4 house. Expert is
trying to determine if they still have a vacuum problem. If so,
another turbo-cart might let them proceed relatively quickly.
Once cold they will do both a dry squeeze and a wet squeeze to
check out orbits before proceeding with shot setup. So it is
hard to imagine collisions any earlier than 2 a.m.. (And easy
to imagine collisions later than that since at moment they
do not have a complete diagnosis of the problem.)
- JJ
Thu Feb 26 22:24:21
From MCR elog:
22:18:17- Mike Geynisman has been unable to cool down the A4
house due to poor vacuum in the region of A44 and A45. We have
paged vacuum guys in an attempt to get another vacuum pump
placed on the area. - BME
-- Thu Feb 26 22:21:12 comment by...BME --
James Mohns and John Featherstone are on their way in. ETA ~1hr. - JJ
Thu Feb 26 22:54:06
The only analysis that I have currently have of beam incident
today is following entry from MCR elog. (There is similar
information in Tevatron elog.)
"The Tevatron quench earlier today was the result of a vacuum
pirani gauge (T:A4TC9W) readback going bad, causing the downstream
A4 beam valve to close on the beam. This bad pirani gauge has been
replaced as the interlocked input to the beam valve. - BME"
It would of course be nice to have a more complete analysis of
the development of the problem/abort/quench but at the minimum
we do know that the failed component has been replaced.
We have to hope that some other problem did not in
fact initiate the failure of the vacuum guage and
that the Tevatron abort system behaved properly.
If a store goes in during the owl shift, I have give the Silicon
Primary and SPL permission to include or hold out Silicon as
they
judge appropriate (even if the beam conditions technically
meet our criteria for including Silicon). - JJ - Ops Manager
Thu Feb 26 23:47:01
Shift Summary: - No beam all shift following a quench on the previous
shift.
- Takasumi Maruyama worked on the SVT crates for two hours.
- David Clark worked on the silicon for about two hours.
- Rick Tesarek and Vivek Tiwari confirmed that the spike killer
is disabled for spike runs using change injection.
- We took cosmics with HV on and Silicon in for 5 hours.
End of Shift Numbers
|
CDF Run II
Runs
Delivered Luminosity 0
Acquired Luminosity 0
Efficiency 100
|
- Robert Harris
Thu Feb 26 23:55:24
| Run Number |
Data Type |
Physics Table |
Begin Time |
End Time |
Live Time |
L1 Accepts |
L2 Accepts |
L3 Accepts |
Live Lumi, nb-1 |
GR |
SC |
RC |
| Totals |
|
|
|
23:55:02 |
:: |
|
|
|
|
|
|
|
- End of Shift Report