2004 CDF E-Log -- Day shift. Thu Feb 26, 2004 |
| SciCo |
DAQ Ace |
Monitoring Ace |
CO |
(Operations Manager) |
| Beate Heinemann |
Tom Schwartz |
Natasha Miladinovic |
Silvia Amerio |
J. J. Schmidt |
Start of Shift Notes:  - store 3256 going at L21.8E30
- COT in particularly unusual configuration: SL1 with 8% reduced HV
plan:
- Silicon is being cooled down: will take about 2 hours. Will then be turned on
- COT will be brought back into the state it was in 1 week ago:
o no nitrogen flow (need HV off for 1 hour)
o SL 1,2 off and 3,4,5 with reduced gains
- keep testing trigger table PHYSICS_TEST_2_02[10,429,434]. Will test this also when Silicon is back
on
Thu Feb 26 08:37:03
Run 179380
Terminated at 2004.02.26 08:35:58 - RunControl
Thu Feb 26 08:37:04
Run 179380
TERMINATE: Nitrogren Flow Stopped Into COT. Detector Config Changed. - Tom x2080
Thu Feb 26 08:58:10
Run 179381
Activated at 2004.02.26 08:57:55 - RunControl
Thu Feb 26 08:59:10
Run 179381
ACTIVATE: Taking some junk data for some folks at CO station while COT is down. ALL COT inhibits masked. - Tom x2080
Thu Feb 26 09:12:18
COT work done: Bob Wagner is turning it back on - Beate
Thu Feb 26 09:15:00
Run 179381
Terminated at 2004.02.26 09:14:02 - RunControl
Thu Feb 26 09:15:01
Run 179381
TERMINATE: COT Back up. - Tom x2080
Thu Feb 26 09:17:10
Run 179382
Activated at 2004.02.26 09:16:58 - RunControl
Thu Feb 26 09:17:39
Run 179382
ACTIVATE: COT now up. Running with it included. - Tom x2080
Thu Feb 26 09:34:39
On Silicon Revival
Once Andy Hocker declares nominal temperature for silicon, please page SPL 722-7483 and David Clark 722-8740. - Rainer
Thu Feb 26 09:39:18
Run 179382
Terminated at 2004.02.26 09:38:53 - RunControl
Thu Feb 26 09:39:19
Run 179382
TERMINATE: Request End Run By Expert. - Tom x2080
Thu Feb 26 09:47:21
MCR called: they want to do collimator studies for half an hour. We turn the HV off/standby and leave CLC on. - Beate
Thu Feb 26 09:49:05
Run 179383
Activated at 2004.02.26 09:48:41 - RunControl
Thu Feb 26 09:50:55
Run 179383
ACTIVATE: xtrp firmware for track ORing. sim track marino. voltage down on detector. - Tom x2080
Thu Feb 26 09:51:14
While bringing HVs down: Had a PSM alarm (1RR18E), CMP trip (part of South Wall), CMU took a while to get to standby. Everything fine now. - natasha
Thu Feb 26 10:14:04
Run 179383
Terminated at 2004.02.26 10:13:44 - RunControl
Thu Feb 26 10:14:25
Run 179383
TERMINATE: Data with HV off for use by experts. - Tom x2080
Thu Feb 26 10:16:26
- MCR called: they finished studies and rescraperd for us. So, we are turning HV back on.
- Silicon is cool
- Beate
Thu Feb 26 10:18:58
Run 179384
Activated at 2004.02.26 10:18:46 - RunControl
Thu Feb 26 10:25:49
Run 179384
ACTIVATE: COT HV Up. SILICON OFF. Running with PHYSICS_TEST_2_02[10,429,433] - Tom x2080
Thu Feb 26 10:40:16
Consumer (LumMon, BeamMon and YMon )are already running with the ONLINE DQM Expert System code implemented. For the moment they are runing without problems. - Olga :: (run 179384)
-- Thu Feb 26 11:31:02 comment by...kaori -- We made a new cdfsoftb0 release 5.3.1pre4c to be current default
and all the monitor related processes are running under this
release. Main difference from previous release is DQM implementation in YMon, LumMon and BeamMon.
Thu Feb 26 10:53:15
Lester Miller is done with Silicon SRC tests so we call
David Clark to power on the Silicon.
- JJ
Thu Feb 26 11:04:39
As requested by expert:
L1 Accept Rate: 14.7 kHz
L2 Accept Rate: 122 Hz
L3 Accept Rate: 22 Hz
Deadtime: 0.62 %
All looks normal.
- Tom
Thu Feb 26 11:07:28



- natasha
Thu Feb 26 11:09:59

- Silvia
-- Thu Feb 26 11:11:30 comment by...Silvia -- COT SL1 and SL2 are off
Thu Feb 26 11:11:30
Run 179384
Terminated at 2004.02.26 11:11:17 - RunControl
Thu Feb 26 11:12:28
Run 179384
TERMINATE: Integrating Silicon. - Tom x2080
Thu Feb 26 11:23:14
Run 179385
Activated at 2004.02.26 11:22:41 - RunControl
Thu Feb 26 11:23:29
Run 179385
ACTIVATE: Silicon Now Included. Running With PHYSICS_TEST_2_02[10,429,433] - Tom x2080
Thu Feb 26 11:47:29
SiliMon crashes (current version) at the first event with
silicon in read-out. Fix should be in soon. We put back
old old SiliMon (4.11.2j). - kaori :: (run 179385)
Thu Feb 26 12:00:13
Rainer called: wants us to keep running with silicon. No DMOD calibrations until further notice from experts. - Beate
Thu Feb 26 12:07:21
Run 179385
Terminated at 2004.02.26 12:06:42 - RunControl
Thu Feb 26 12:07:47
Run 179385
TERMINATE: Quench. Ending Run. - Tom x2080
Thu Feb 26 12:09:24
Tevatron quenched - Beate
Thu Feb 26 12:15:43
Performed Post-Quench Checkout. Run Config in DaqTest/SVX/ColdStart (kept Proxy the same). Got through coldstart fine. Unmarked Silicon Cells. No new pinkies. - Tom
Thu Feb 26 12:17:44
Since yesterday, I have experienced 3 times, netscape crashed
after making entries in e-log, hitting preview, and instant after
hitting 'close' in the preview window. Netscape I was using
is the very old version running in the control room pc's. - kaori
Thu Feb 26 12:18:17
Run 179381
RUNSTATUS: Marked Bad, explanation:
COT
SVX
ISL
L00
SVT
- cdfscico
Thu Feb 26 12:23:15
Run 179382
RUNSTATUS: Marked Bad, explanation:
SVX
ISL
L00
SVT
- cdfscico
Thu Feb 26 12:25:05
Run 179384
RUNSTATUS: Marked Bad, explanation:
SVX
ISL
L00
SVT
- cdfscico
Thu Feb 26 12:25:22
| Date | Time | BLM | Dose |
| 2004.02.26 | 12:24:40 | W Inner BLM | 776.37 | RADS |
| 2004.02.26 | 12:24:40 | W Outer BLM | 6.49 | RADS |
| 2004.02.26 | 12:24:40 | E Inner BLM | 81.48 | RADS |
| 2004.02.26 | 12:24:40 | E Outer BLM | 739.91 | RADS |
Integrated dosage - natasha
Thu Feb 26 12:30:37
 | blm summary |
- natasha
-- Thu Feb 26 13:28:22 comment by...Rainer -- The correct plot is
here
Thu Feb 26 12:34:27
Run 179386
ACTIVATE: Cal QIE. ALL HV ON. - Tom x2080
Thu Feb 26 12:34:48
Run 179386
TERMINATE: Cal QIE. ALL HV On. - Tom x2080
Thu Feb 26 12:41:52
post quench checkout procedure completed. Silicon went through config without problems. I will not unmark the pink cells (there is a number of them) since David told me not to worry about them. - natasha
Thu Feb 26 12:45:14
Just after quench it took CMP 3 tries to get back up. - natasha
Thu Feb 26 12:50:27
Run 179387
ACTIVATE: TOF QIE Calib. - Tom x2080
Thu Feb 26 12:51:11
Run 179387
TERMINATE: TOF QIE Calib. - Tom x2080
Thu Feb 26 12:54:12
Run 179388
ACTIVATE: SMX QIE Calib. - Tom x2080
Thu Feb 26 12:54:19



- natasha
-- Thu Feb 26 12:55:22 comment by...natasha -- Plots showing quench-time losses. Proton abort gap losses spiked quite a bit.
Thu Feb 26 12:55:29
plug laser on anticipating calib. - Tom
Thu Feb 26 12:55:56
Run 179388
TERMINATE: SMX QIE Calib. - Tom x2080
Thu Feb 26 12:57:13
COT, muon detectors and Plug all on standby. TOF off. Silicon still on (we did not get instructions from experts about this). - natasha
-- Thu Feb 26 13:01:03 comment by...rainer -- on ? I hope you mean standby.
Thu Feb 26 12:58:06
Run 179389
ACTIVATE: COT Calib. - Tom x2080
Thu Feb 26 12:58:07
Run 179389
TERMINATE: COT Calib. - Tom x2080
Thu Feb 26 13:00:13
Run 179390
ACTIVATE: Muon Calib. - Tom x2080
Thu Feb 26 13:00:59
 | BLM summary... |
- natasha
-- Thu Feb 26 13:27:31 comment by...rainer -- so there is significant radiation dose in the last bin of the BLM plot. questions:
something happened on the 200 mu s scale. this something usually indicates trouble with the abort kicker system.
abort gap loss rates were below 10 kHz at the time of the abort. can we trust the rates for clean aborts ?
the circumstances of this quench should be thoroughly explained.
-- Thu Feb 26 15:30:27 comment by...rainer -- A0 has been very hot in this quench - see MCR elog
Thu Feb 26 13:01:09
Run 179390
TERMINATE: Muon Calib. - Tom x2080
Thu Feb 26 13:03:48
Run 179391
ACTIVATE: TOF TAC Calib. - Tom x2080
Thu Feb 26 13:05:41
Run 179391
TERMINATE: TOF TAC Calib. - Tom x2080
Thu Feb 26 13:12:23
Run 179392
Activated at 2004.02.26 13:11:49 - RunControl
Thu Feb 26 13:12:31
Run 179392
ACTIVATE: PMT Spike run Calib. - Tom x2080
Thu Feb 26 13:13:58
MCR called: they will be down for at least 1-1.5 hours and are going into access. They still don't know the reason for the quench. We are investigating whether we want an access too. - Beate
Thu Feb 26 13:21:35
Run 179392
Terminated at 2004.02.26 13:21:05 - RunControl
Thu Feb 26 13:21:36
Run 179392
TERMINATE: PMT Spike Calib. - Tom x2080
Thu Feb 26 13:23:39
PMT Spike Calib: L1 Rate 52.6 Hz. - Tom
Thu Feb 26 13:25:48
Run 179393
ACTIVATE: CLC QIE Calib. - Tom x2080
Thu Feb 26 13:27:31
Run 179393
TERMINATE: CLC QIE Calib. Note: Expert just worked on CLC crate. - Tom x2080
Thu Feb 26 13:29:01
Run 179394
ACTIVATE: CLC QIE Calib. NOTE: Expert just finished working on clc crate. - Tom x2080
Thu Feb 26 13:31:10
Run 179394
TERMINATE: CLC QIE Calib. - Tom x2080
Thu Feb 26 13:31:15
PTM alarm -- sensor failure. I went upstairs and checked the temperatures themselves -- both central and plug cal look good so far. Tried calling the expert, will try later. - natasha
Thu Feb 26 13:32:36
Reset CLC Admems. - Tom
-- Thu Feb 26 13:54:44 comment by...Tom -- Hung on Reset using VisionDemo.
-- Thu Feb 26 13:55:30 comment by...Tom -- TEVMON warning came on during calib. Proton Losses too low...possible lost of inputs.
-- Thu Feb 26 13:55:44 comment by...Tom -- experts working on it.
Thu Feb 26 13:36:20
Run 179395
ACTIVATE: CEM LED Calib. - Tom x2080
Thu Feb 26 13:37:31
Run 179395
TERMINATE: CEM LED Calib. - Tom x2080
Thu Feb 26 13:54:42
Run 179396
ACTIVATE: CLC QIE Calib. - Tom x2080
Thu Feb 26 13:55:40
Made sure that MCR will definitely call us before beam is put into the machine! - Beate
Thu Feb 26 14:19:51
Run 179397
ACTIVATE: BSC QIE Calib. - Tom x2080
Thu Feb 26 14:20:46
Run 179397
TERMINATE: BSC QIE Calib. - Tom x2080
Thu Feb 26 14:32:52
Run 179398
TERMINATE: changing run config. - Tom x2080
Thu Feb 26 14:32:52
I fixed the PTM sensor failure by taking the problem sensor [PE10, Dallas sensor 1] out of the configuration, and the alarm is gone. The sensor was reading too high a value and as a results the RMS of the 9 Dallas sensors was out of range. - natasha
Thu Feb 26 14:33:41
All HVs up in preparation for cosmics run. - natasha
Thu Feb 26 14:36:42
| | Plug Laser Calib had to be scrapped. Laser off. |
- Tom
Thu Feb 26 14:39:42
Run 179399
Activated at 2004.02.26 14:39:30 - RunControl
Thu Feb 26 14:40:37
Run 179399
ACTIVATE: COSMICS_SILICON_TAPE COSMICS[12,391,403] - Tom x2080
Thu Feb 26 14:45:25
b0svt06 crate hung (H and U went red in Vxworks system monitor). Shepherded twice and went back to normal. - Tom
Thu Feb 26 14:56:58
COT calibration results:
NumBad cells = 3 (>1)
NumBad cables = 2 (>1)
- Silvia
Thu Feb 26 15:35:18
We have swapped the 2300 CPU in crate b0clc00 for a 2400.
This crate has one of the longer readout times and this should help
speed it up.
We found that the new CPU hangs VISIONdemo (if it is run on a PC as
opposed to the crate itself) when doing the crate reset as the last
step in the CLC QIE calibration. In this case the reset is actually
done correctly but you have to control-c out of VISIONdemo.
We have switched the instructions on the web page
to include a vxlogin to the crate,
in which case VISIONdemo will work the same for all CPU's.
Problems to DAQ pager. - Ray Culbertson and Ming Wang :: (run 179399)
Thu Feb 26 15:35:48



- Silvia
-- Thu Feb 26 15:48:08 comment by...Silvia -- SMX calibration results (run 179388)
Thu Feb 26 15:47:45
Run 179399
Terminated at 2004.02.26 15:47:22 - RunControl
Thu Feb 26 15:47:46
Run 179399
TERMINATE: Expert wants to remove some crates. - Tom x2080
Thu Feb 26 15:54:26
Run 179400
Activated at 2004.02.26 15:53:27 - RunControl
Thu Feb 26 15:54:27
Run 179400
ACTIVATE: Running COSMICS_SILICON_TAPE COSMICS[12,391,403]. No VRB or FIB crates are being used as requested by expert. - Tom x2080
Thu Feb 26 15:55:30
| Run Number |
Data Type |
Physics Table |
Begin Time |
End Time |
Live Time |
L1 Accepts |
L2 Accepts |
L3 Accepts |
Live Lumi, nb-1 |
GR |
SC |
RC |
|
179379
x2BCB3 |
BEAM |
PHYSICS_TEST_2_02 [10,429,433] |
05:06:24 |
08:06:27 |
02:54:41 |
141,264,440 |
1,454,423 |
266,250 |
244.877 |
0 |
1 |
1 |
|
179380
x2BCB4 |
BEAM |
PHYSICS_TEST_2_02 [10,429,433] |
08:23:51 |
08:35:58 |
00:00:00 |
0 |
0 |
|
0.000 |
|
1 |
0 |
|
179381
x2BCB5 |
BEAM |
PHYSICS_TEST_2_02 [10,429,433] |
08:57:55 |
09:14:02 |
00:16:03 |
1,612,204 |
27,566 |
13,192 |
20.255 |
0 |
0 |
1 |
|
179382
x2BCB6 |
BEAM |
PHYSICS_TEST_2_02 [10,429,433] |
09:16:58 |
09:38:53 |
00:21:43 |
14,020,377 |
132,042 |
28,734 |
27.222 |
1 |
1 |
1 |
|
179383
x2BCB7 |
BEAM |
PHYSICS_TEST_2_02 [10,429,433] |
09:48:41 |
10:13:44 |
00:01:44 |
119,749,071 |
19,523 |
13,266 |
0.000 |
|
1 |
0 |
|
179384
x2BCB8 |
BEAM |
PHYSICS_TEST_2_02 [10,429,433] |
10:18:46 |
11:11:17 |
00:52:09 |
40,535,609 |
351,436 |
70,111 |
62.010 |
1 |
1 |
1 |
|
179385
x2BCB9 |
BEAM |
PHYSICS_TEST_2_02 [10,429,433] |
11:22:41 |
12:06:42 |
00:42:34 |
31,103,353 |
412,640 |
91,172 |
48.938 |
1 |
1 |
1 |
| Totals |
|
|
|
15:55:02 |
05:08:57 |
348,285,054 |
2,397,630 |
482,725 |
403.302 |
|
|
|
- End of Shift Report
Thu Feb 26 15:58:39
Shift Summary: history:
=======
- took data in store 3256
- COT put back into "normal" configuration: SL1,2 off, 345 reduced gains
- Silicon cooled down and was turned on
- just after Silicon was back in Tevatron quenched!
- took all calibrations except Plug Laser
- PTM sensor failure fixed by our ACE Natasha
ongoing work:
============
- are in quiet time: Tevatron will call us before they put beam in machine
- PCAL11 looks bad in calibrations: Mike L. will powercycle East Plug
- Lester working on Silicon (SRC)
- Rick Tesarek spike run after power cycling
End of Shift Numbers
|
CDF Run II
Runs 179379, 179381, 179382, 179384, 179385
Delivered Luminosity 131.7
Acquired Luminosity 109.8
Efficiency 83.3
|
- Beate