2004 CDF E-Log -- Eve shift. Wed Feb 25, 2004 |
| SciCo |
DAQ Ace |
Monitoring Ace |
CO |
(Operations Manager) |
| Robert Harris |
Chris Marino |
Simon Sabik |
Josh Tuttle |
JJ Schmidt |
Start of Shift Notes:  Inherit store 3256 with luminosity of 52E30 and running with degraded COT (SL 1 HV reduced by
8%) and silicon off. Expect
to run this way for about 3 1/2 hours more. After that there
is no plan currently.
Wed Feb 25 16:12:51
Run 179358
ACTIVE: BUSY Timeout caused by evb error: b0eb15
Busy Condition in VRB/EVB forwarded by crates:
CCAL_10 Busy conditions are produced by the VRB and are forwarded
by the front end crates to the busy crosspoint. Busy
conditions do not represent a problem with the front end
crates themselves, but with the EVB system. - Christopher x2080
-- Wed Feb 25 16:13:25 comment by...Christopher -- HRR Recovered
Wed Feb 25 16:31:48
Jim the Cryo tech called and said he will be rebooting S3 and it might cause some IFIX errors. We should ignore them. - Robert Harris
Wed Feb 25 17:21:08
Checked following calibrations from Day shift (DBANA):
- BSCQIE (Run 179351) = fine
- CALLED (Run 179337) = fine
- CALQIE (Run 179347) = fine
- CLCQIE (Run 179335) = fine
- josh
Wed Feb 25 17:27:33



- Simon
-- Wed Feb 25 17:28:29 comment by...Simon -- B0ABSM spiked to 85000 and came back to normal.
Wed Feb 25 17:36:19
 | Big lost proton spike. |
- Simon
Wed Feb 25 17:37:45
CMX tripped. South West channels 11 and 12. Ramped back up. This happened at the same time as the lost proton spike. - Simon :: (run 179358)
Wed Feb 25 17:40:07
Carla Grosso-Pilcher indicates that a tower in the WHA is a
little "warm" due to a problem with a single channel of it's
ADMEM. She says that it seems to be cooling down now . . . - Robert Harris
Wed Feb 25 17:49:51
Vadim tells us that he is going to power down the pulser crate,
which is not in the data taking, but that we should see it on
the Global Alarms. We should ignore the alarm. - Robert Harris
-- Wed Feb 25 17:56:41 comment by...Robert Harris -- He does this, and this causes a trigger inhibit halting the run. I tell him to put it back, he does, and we are running again.
The board was a Pulsar board (not pulser) for the L2 system and Vadim Rusu says that they are not read out and should not be in a trigger inhibit. I tell him he should consult with the rest of L2 trigger system personnel.
-- Wed Feb 25 18:15:56 comment by...Burkard -- So I being part of the rest of the L2 trigger system personnel came over to B0. We caught Bill Badgett, who helped us to mask the crate (2RR29C) in the PSM.
Wed Feb 25 18:08:03
Bill Badgett helps out on the Pulsar crate problem. They mask off the crate in IFIX and then they are able to pull the board without creating either an alarm or a trigger inhibit. Vadim
Rusu is now going to do work in that crate. - Robert Harris
Wed Feb 25 18:47:21
Run 179358
ACTIVE: Received another scalar monitor message:
Attention!!!. FERML_HIGH_DEADTIME !!!. - Christopher x2080
Wed Feb 25 19:07:50



- Simon
-- Wed Feb 25 19:08:58 comment by...Simon -- Big proton loss and abort gap loss rate at the same time (17:30).
Wed Feb 25 20:29:50
We paused the run so that Takasumi Maruyama could pull out
a board from SVT06 crate. - Robert Harris
Wed Feb 25 20:43:46
Run 179358
Terminated at 2004.02.25 20:43:19 - RunControl
Wed Feb 25 20:44:05
Run 179358
TERMINATE: switch to lower lum table
Lum 37.5 - Christopher x2080
Wed Feb 25 20:46:22
restarted Stage0 consumer monitor during run change - josh
Wed Feb 25 20:48:35
Run 179361
Activated at 2004.02.25 20:48:02 - RunControl
Wed Feb 25 20:48:36
Run 179361
ACTIVATE: Physics 2_02[2,424,431] - Christopher x2080
Wed Feb 25 20:49:35



- Simon
Wed Feb 25 21:18:43
JJ gives us a plan for the remainder of the store. The first
step is to stop the current running with the COT at 10 p.m.
and let Vadim and Burhard perform their isolist fiber tests for 30-60 minutes. I call Vadim and Burhard and they agree to come in at 10 p.m. for the tests. - Robert Harris
Wed Feb 25 21:28:36
Run 179358
RUNSTATUS: Marked Bad, explanation:
Silicon is off, SL1 of COT is at 8% reduced HV for Aseets test.
COT
SVX
ISL
L00
- cdfscico
Wed Feb 25 21:53:37
Run 179361
ACTIVE: I noticed the VxWorks node monitoring showed b0cot12 as red with code U.
Within a few minutes L2 timeout was received adn b0cot12 failed HALT transition
I rebooted and shepherded crate before proceeding with HRR, adnd the system recovered. - Christopher x2080
Wed Feb 25 22:08:58
Run 179361
Terminated at 2004.02.25 22:08:48 - RunControl
Wed Feb 25 22:09:22
Run 179361
TERMINATE: to bring down COT HV and run some tests - Christopher x2080
Wed Feb 25 22:14:18
Run 179362
Activated at 2004.02.25 22:14:08 - RunControl
Wed Feb 25 22:15:07
Run 179362
ACTIVATE: Physics_2_02[2,424,431] - Christopher x2080
Wed Feb 25 22:24:22
JJ informs us that Aseet is coming in to put the COT back in the state it was in one week ago. - Robert Harris
-- Wed Feb 25 22:33:10 comment by...JJ -- JJ also called XFT pager (Ben answered) to verify that
XFT was set in correct mode with SL2 masked on and
SL4 set to 3 misses. Ben says XFT is still in this mode.
Wed Feb 25 22:31:36



- Simon
Wed Feb 25 22:44:07
Aseet arrives and starts putting the COT in it's old configuration. JJ says that when he is finished we can bring up the COT HV. Burhard and Vadim are currently doing their isolist fiber test run. - Robert Harris
Wed Feb 25 22:46:47
Run 179361
RUNSTATUS: Marked Bad, explanation:
Silicon off, COT on with SL1 at 8% reduced HV for Aseets test
COT
SVX
ISL
L00
- cdfscico
Wed Feb 25 22:52:12
Asset is now in his office and we are supposed to call him over when we bring up the COT high voltage. - Robert Harris
Wed Feb 25 23:05:48
Run 179362
Terminated at 2004.02.25 23:05:22 - RunControl
Wed Feb 25 23:06:52
Run 179362
TERMINATE: end to give COT and MUON crates to BB - Christopher x2080
Wed Feb 25 23:12:02
Run 179363
Activated at 2004.02.25 23:11:34 - RunControl
Wed Feb 25 23:12:08
Run 179363
ACTIVATE: Physics 2_02[2,424,431] -- tests ongoing - Christopher x2080
Wed Feb 25 23:26:42
Run 179362
RUNSTATUS: Marked Bad, explanation:
Silicon off and COT off. Isolist fiber test run.
COT
SVX
ISL
L00
- cdfscico
Wed Feb 25 23:30:09
Run 179363
Terminated at 2004.02.25 23:29:39 - RunControl
Wed Feb 25 23:30:10
Run 179363
TERMINATE: end of L2 pulsar testing - Christopher x2080
Wed Feb 25 23:31:47
Bringing up the COT HV in compromised mode (SL1,2 off, SL3,4,5 reduced). - Robert Harris
Wed Feb 25 23:40:34



- Simon
Wed Feb 25 23:48:17
Have programmed all TDCs in the system to DSP V45, and
marked the bankVersions as 1 in the hdwdb.
We are running with PHYSICS_TEST_2_02 [10,429,434], and
l3Tag=434 means there is a small patch to work around
a problem in the L3DaqErrorFilter, which was causing
every event to pass.
Also, we are running with updated code in the FrontEnd
to provide more information on the low-level bc mismatch
errors with this DSP version.
- W.Badgett :: (run 179364)
Wed Feb 25 23:54:34
Run 179364
Activated at 2004.02.25 23:53:45 - RunControl
Wed Feb 25 23:55:36
| Run Number |
Data Type |
Physics Table |
Begin Time |
End Time |
Live Time |
L1 Accepts |
L2 Accepts |
L3 Accepts |
Live Lumi, nb-1 |
GR |
SC |
RC |
|
179358
x2BC9E |
BEAM |
PHYSICS_HIGHLUM_2_02 [1,420,427] |
14:42:20 |
20:43:19 |
05:42:44 |
146,805,399 |
5,799,818 |
909,603 |
951.325 |
0 |
1 |
1 |
|
179361
x2BCA1 |
BEAM |
PHYSICS_2_02 [2,424,431] |
20:48:02 |
22:08:48 |
01:17:27 |
78,853,498 |
943,027 |
169,545 |
166.168 |
0 |
1 |
1 |
|
179362
x2BCA2 |
BEAM |
PHYSICS_2_02 [2,424,431] |
22:14:08 |
23:05:22 |
00:43:48 |
6,390,992 |
113,256 |
48,093 |
88.209 |
0 |
0 |
1 |
|
179363
x2BCA3 |
BEAM |
PHYSICS_2_02 [2,424,431] |
23:11:34 |
23:29:39 |
00:14:45 |
1,857,933 |
34,548 |
15,088 |
28.546 |
|
0 |
1 |
| Totals |
|
|
|
23:55:02 |
07:58:45 |
233,907,822 |
6,890,649 |
1,142,329 |
1234.249 |
|
|
|
- End of Shift Report
Wed Feb 25 23:55:37
Run 179364
ACTIVATE: Physics_Test_2_02[10,429,434] -- Bill Badgett's test - Christopher x2080
Thu Feb 26 00:10:16
Shift Summary: - Took data with Silicon off and COT on with SL1 at 8%
reduced HV
for Assets test. Brought down the COT HV afterwards.
- Vadim and Burhard did Isolist Fiber Test Runs with SVX and COT
off. Bill Badgett simultaneously did tests with a couple of
crates.
- Asset put the COT back in its stable configuration: SL1-2 off,
SL3,4,5 reduced. We bring the COT HV back up.
- Bill Badgett started a test run for the TDC DSP microcode at
end of shift.
JJ has allotted him 1-2 hours for this run.
- Robert Harris
-- Thu Feb 26 00:18:27 comment by...Guram -- Luminosity summary shows following:
Begin shift or beam at 16:00:10
End shift or beam at 23:58:24
Delivered luminosity: 36.74
Acquired luminosity: 0.04
Totals
Date: 2004.02.25
Shift: eve
Delivered luminosity:36.7 nb-1
Acquired luminosity: 0.0 nb-1
Efficiency: 0.1
I guess something is wrong with luminosity summary, since "End of
Shift Report" above shows 1.2 pb^-1 of total live luminosity, and
from the acnet plot we know that about 1.4 pb^-1 were delivered.
-- Thu Feb 26 08:21:07 comment by...j. patrick -- The crate b0clc01 was rebooted at 23:38. This crate is
the source of the integrated luminosity, rebooting
the crate will zero the value.
Thu Feb 26 00:18:58
Got TOF heart bit. SMACS crashed. Had to kill and restart it.
Things are back to normal.
(entry outside this shift's time range
)
- Andrew