2004 CDF E-Log -- Owl shift. Tue Feb 24, 2004
SciCo DAQ Ace Monitoring Ace CO (Operations Manager)
Guram Chlachidze Ian Vollrath Andrew Ivanov Oleg Poukhov J.J. Schmidt


Start of Shift Notes:  

Take over store 3254 at L=35E30. Taking data without silicon. 

Tue Feb 24 00:10:55
ccr trip. paused run, brought hv back up. all ok.
 - ian :: (run 179314)
Tue Feb 24 00:59:52
On previous shift got a TOF heart beat alarm. previous ace   
restarted smacs. we were back running for ~1min until we got a   
TOF HV trigger inhibit. turns out the "play" button wasn't   
pushed. did this. were back running for several minutes and then  
another TOF HV inhibit. notice all of crate 1 HV was blue (off)  
as well as two boards from crate 2. tried restarting smacs   
again. didn't help. eventually brought tof hv back via ifix. this  
seemed to work.  
 - Ian & Andrew
-- Tue Feb 24 01:21:43 comment by...Guram --  
We paged TOF expert to check if the current HV values are 
correct. According to his instructions monitoring ace 
checked HV at 1st floor with the monitoring program, they 
look OK. CO checked YMon plots and they are OK as well.

Tue Feb 24 01:12:23
X, Y Beam Positions from BeamMon Plot (Store 3254).
 - Oleg
Tue Feb 24 01:12:58
 - 00:00 - 1:00 status plots - Andrew
Tue Feb 24 02:07:40
 - 1:00 - 2:00 status plots - Andrew
Tue Feb 24 02:29:52
done timeout from pcal08 - red in vxworks. successfully shepherded pcal08. back running.
 - ian :: (run 179314)
Tue Feb 24 02:57:59
got error: 

(MLE) b0l2de00:SpyAlpha:2:55:01 AM-> 
ClistMon: Error on pass 0, cluster 0: 0 != 1 

hrr worked.
 - ian :: (run 179314)
Tue Feb 24 03:04:22
 - 2:00-3:00 status plots - Andrew
Tue Feb 24 03:34:19 Question to YMon experts:
When I choose any NON-SLIDE plot without "Auto Update" mode I see the graph, which I've updated before manually (for example 1 or 2 hours ago). Usually when I want to check a set of plots, it is much more convenient to remove "Auto Update" during this checking. But in this case there is a chance that you will look at old, not updated plots.
Is it purposely done in YMon, or just a failure ?  - Oleg :: (run 179314)
-- Tue Feb 24 07:02:43 comment by...kaori --  
It is somehow how it works at a moment in HistoDisplay.
We need to disable "auto update" when we check each plot, then
need to enable again, after checking plots.

Tue Feb 24 04:14:10
 - 3:00-4:00 status plots - Andrew
Tue Feb 24 04:16:10
got error: 

(MLE) b0l2de00:SpyAlpha:4:15:14 AM-> 
ClistMon: Error on pass 0, cluster 0: 0 != 3 

hrr worked.
 - ian :: (run 179314)
Tue Feb 24 05:06:56
PSM alarm and trigger inhibit traced to BSU_SE_1 and BSU_SE_2  
crates. Cleared itself.
 - Andrew
-- Tue Feb 24 05:09:17 comment by...ian --  
svt06 red in vxworks, rc got stuck after inhibit. successfully shepherded svt06. back
running.

Tue Feb 24 05:10:33
 - 4:00-5:00 status plots - Andrew
Tue Feb 24 05:16:20
(MLE) b0l2de00:SpyAlpha:5:15:27 AM-> 
ClistMon: Error on pass 2, cluster 0: 3 != 0 

hrr worked
 - ian :: (run 179314)
Tue Feb 24 06:10:29
 - 5:00-6:00 status plots - Andrew
Tue Feb 24 07:42:48
 - 6:00 - 7:30 status plots - Andrew
Tue Feb 24 07:55:46
Run Number Data Type Physics Table Begin Time End Time Live Time L1 Accepts L2 Accepts L3 Accepts Live Lumi, nb-1 GR SC RC
179314 x2BC72 BEAM PHYSICS_2_02 [2,424,431] 23:22:04 07:46:10 454,519,572 5,627,092 916,215 798.133 1
Totals 07:55:02 07:46:10 454,519,572 5,627,092 916,215 798.133
 - End of Shift Report
Tue Feb 24 08:16:30 Shift Summary:
We inhereted store 3254 at L=35*E30, taking data w/o svx.


- 00:01 previous shift got a TOF heart beat alarm. previous ace 
        restarted smacs. we were back running for ~1min until we got a 
        TOF HV trigger inhibit. turns out the  

End of Shift Numbers
CDF Run II

Runs                   179314
Delivered Luminosity   813  
Acquired Luminosity    729  
Efficiency             89.7

 - Guram
-- Tue Feb 24 08:17:23 comment by...Guram --  
End of shift:
We inhereted store 3254 at L=35*E30, taking data w/o svx.
- 00:01 previous shift got a TOF heart beat alarm. previous ace
        restarted smacs. we were back running for ~1min until we got a
        TOF HV trigger inhibit. turns out the "play" button wasn't
        pushed. did this. were back running for several minutes and then
        another TOF HV inhibit. notice all of crate 1 HV was blue (off)
        as well as two boards from crate 2. tried restarting smacs
        again. didn't help. eventually brought tof hv back via ifix. this
        seemed to work.
- 05:06 PSM alarm and trigger inhibit traced to BSU_SE_1 and BSU_SE_2
        crates. Cleared itself

In general uneventful shift, only a few errors from b0l2de00:SpyAlpha,
hrr done.