2004 CDF E-Log -- Day shift. Tue Feb 24, 2004 |
| SciCo |
DAQ Ace |
Monitoring Ace |
CO |
(Operations Manager) |
| Beate Heinemann |
Tom Schwartz |
Susana Cabrera |
Silvia Amerio |
J. J. Schmidt |
Start of Shift Notes:  taking over store 3254 at L=23E30. Plan is to take data.
Tue Feb 24 08:58:35
TRIP in SE BMU channel 72:
We have tried twice the cicle on->standby->on, on->standby->off->standby->on and
the trip did not clear off.
At the end, we repeated the cicle on->standby->on for the whole
BMU detector and finally we recover from the trip.
- Susana.
Tue Feb 24 09:12:31



- Susana.
Tue Feb 24 09:13:06
The BMU trip is back, working with the expert. - Susana.
-- Tue Feb 24 09:20:00 comment by...Tom -- Masked off Trip:MUO1 and IFIX:MU HV. all channels ok except channel 72 in BMU. I will halt
the run if anything else changes. Just to clarify: This data will be ok except for BMU Channel 72
data. I will halt the run if anything else changes.
Tue Feb 24 09:21:00
We have changed current default cdfsoftb0 release to 5.3.1pre4a.
All the online montior related processes were restarted with this new release. - ryo and kaori :: (run 179314)
-- Tue Feb 24 09:27:43 comment by...ryo and kaori -- Following monitors were running under 5.3.1pre4a already:
Event display
XMon
TrigMon
ObjectMon
YMon
SiliMon
DAQMon
Stage0
Following monitors were swithed from 5.3.1pre1d to 5.3.1pre4a:
LumMon
BeamMon
SVXMon(not running because silicon is not running.)
Tue Feb 24 09:58:29



- Susana.
Tue Feb 24 11:40:25



- Susana
Tue Feb 24 12:02:59
The bad bit in trigger tower (eta=11, phi=15, had) cured itself
between runs 179286 and 179287, before any human intervention...
- carla
Tue Feb 24 12:14:56
BMU HV trip comments: This HV channel recently(12hr) was swapped upstairs at the CAEN power supply. We are not certain this problem is in the collision hall. For now the HV on sector 72 is off (which clears the inhibit according to Phil S). It is possible that returning the HV cabling to the previous configuration may help. - Dan C & Phi S
Tue Feb 24 12:55:42



- Susana
Tue Feb 24 14:03:25



- Susana.
Tue Feb 24 14:15:08
Alarm in the GAS SYSTEMS " TE-SEXBUB, the current value of the temperature is 43.7 F and the
high limit is 37 F,
the cryotech person is woorking on it, it has been silienced
- Susana.
Tue Feb 24 14:44:52
 | BMU Cells East: HV on sector 72 off. |
- Silvia
Tue Feb 24 15:03:43



- ryo
-- Tue Feb 24 15:07:07 comment by...ryo -- These are recent beam positon X,Y and slope etc...
run 179230 is at 02/18/04
Tue Feb 24 15:11:05



- Susana.
Tue Feb 24 15:38:36
Date Time BLM Dose
2004.02.24 15:34:31 W Inner BLM 735.77 RADS
2004.02.24 15:34:31 W Outer BLM 0.00 RADS
2004.02.24 15:34:31 E Inner BLM 20.67 RADS
2004.02.24 15:34:31 E Outer BLM 621.32 RADS
Integrated dosage
- Susana.
Tue Feb 24 15:43:04
 | s |
- Susana
-- Tue Feb 24 15:44:22 comment by...Susana -- SVXRAD0 incerases from 510 to 700 RADS, the threshold during
stores is 1000 RADS (WARNING)
-- Tue Feb 24 16:03:07 comment by...Susana. -- Sorry, a lapsus, the threshold during stores is 3000 RADS
Tue Feb 24 15:49:30
Shift Summary:
- took data of store 3254: store will continue until tomorrow.
- BMU trip could not be reset. Running with lower HV on that channel
- else data taking smooth, still running with COT on and Silicon off
End of Shift Numbers
|
CDF Run II
Runs 179314
Delivered Luminosity 557.9
Acquired Luminosity 516.8
Efficiency 92.6
|
- Beate
Tue Feb 24 15:55:27
| Run Number |
Data Type |
Physics Table |
Begin Time |
End Time |
Live Time |
L1 Accepts |
L2 Accepts |
L3 Accepts |
Live Lumi, nb-1 |
GR |
SC |
RC |
|
179314
x2BC72 |
BEAM |
PHYSICS_2_02 [2,424,431] |
23:22:04 |
|
15:15:51 |
856,233,812 |
9,698,356 |
1,600,100 |
1331.614 |
|
|
1 |
| Totals |
|
|
|
15:55:02 |
15:15:51 |
856,233,812 |
9,698,356 |
1,600,100 |
1331.614 |
|
|
|
- End of Shift Report
Tue Feb 24 16:00:43
Shift Summary: see above
- beate
Tue Feb 24 16:00:53



- Susana.