2004 CDF E-Log -- Eve shift. Fri Feb 13, 2004 |
| SciCo |
DAQ Ace |
Monitoring Ace |
CO |
(Operations Manager) |
| Pat Lukens/Doug G |
Vadim |
Natasha |
Olga/ |
Mary C |
Start of Shift Notes:  
* --- shot setup to start at about 1730
- special COT/trigger runs
- page cheng-ju, mary and kaori
Fri Feb 13 16:18:13
Run 179073
TERMINATE: stop run - Wojtek/Burkard/Vadim
Fri Feb 13 16:25:44
Run 179074
ACTIVATE: Try to log some more data onto the Pulsar CLIST - Wojtek/Burkard/Vadim
Fri Feb 13 16:51:43
Run 179074
TERMINATE: Get some more events to tape - Wojtek/Burkard/Vadim
Fri Feb 13 16:55:14
Run 179075
ACTIVATE: Record some more events - Wojtek/Burkard/Vadim
Fri Feb 13 17:14:53
COT HV for SL1 and SL2 set to zero. HV for SL3 and 5 lowered
to 96%. SL4 still at 100% for XFT Tests.
Note that the left bar in the HV bar graph display will not come
up now since two SL are set to zero. Trigger inhibits for SL1,2
have been disconnected so it should work correctly.
- Aseet, Bob, Kevin
Fri Feb 13 17:36:46
Run 179075
TERMINATE: stop to start new run - Wojtek/Burkard/Vadim
Fri Feb 13 17:39:16
Run 179076
ACTIVATE: next test run - Wojtek/Burkard/Vadim
Fri Feb 13 17:55:57
Run 179076
TERMINATE: end test to do quiet time calibration - Wojtek/Burkard/Vadim
Fri Feb 13 17:58:09
Run 179077
ACTIVATE: Calorimeter QIE Calibration - Wojtek/Burkard/Vadim
Fri Feb 13 17:58:10
Run 179077
TERMINATE: Calorimeter QIE Calibration - Wojtek/Burkard/Vadim
Fri Feb 13 18:00:20
Run 179078
ACTIVATE: CLC QIE Calibration - Wojtek/Burkard/Vadim
Fri Feb 13 18:00:21
Run 179078
TERMINATE: CLC QIE Calibration - Wojtek/Burkard/Vadim
Fri Feb 13 18:02:18
Run 179079
ACTIVATE: BSC QIE Calibration - Wojtek/Burkard/Vadim
Fri Feb 13 18:02:19
Run 179079
TERMINATE: BSC QIE Calibration - Wojtek/Burkard/Vadim
Fri Feb 13 18:04:30
Run 179081
ACTIVATE: CEM LED Calibration - Wojtek/Burkard/Vadim
Fri Feb 13 18:05:35
Run 179081
TERMINATE: CEM LED Calibration - Wojtek/Burkard/Vadim
Fri Feb 13 18:09:12
Run 179082
ACTIVATE: CMX QIE Calibration - Wojtek/Burkard/Vadim
-- Fri Feb 13 18:11:16 comment by...Vadim -- I ment SMX
Fri Feb 13 18:09:56
Run 179082
TERMINATE: SMX QIE Calibration - Wojtek/Burkard/Vadim
Fri Feb 13 18:11:07
Run 179084
ACTIVATE: COT Calibration - Wojtek/Burkard/Vadim
Fri Feb 13 18:11:55
Run 179084
TERMINATE: COT Calibration - Wojtek/Burkard/Vadim
Fri Feb 13 18:14:05
Run 179086
ACTIVATE: Muon Calibration - Wojtek/Burkard/Vadim
Fri Feb 13 18:15:33
Run 179086
TERMINATE: Muon Calibration - Wojtek/Burkard/Vadim
Fri Feb 13 18:17:25
Run 179088
ACTIVATE: TOF TAC Calibration - Wojtek/Burkard/Vadim
Fri Feb 13 18:18:37
Run 179088
TERMINATE: TOF TAC Calibration - Wojtek/Burkard/Vadim
Fri Feb 13 18:28:27
Run 179089
Activated at 2004.02.13 18:28:11 - RunControl
Fri Feb 13 18:28:28
MCR called. They are about to inject protons.
- Doug
Fri Feb 13 18:30:05
Forgot to mention that about 15 minutes ago the CEM CHA WHA
boxes on global alarms went red then grey. Nikolai says there's
a problem w/ slow controls software. Paged Steve Hahn. He's
here working on it.
- Doug
-- Fri Feb 13 18:58:32 comment by...Doug -- Steve's first try didn't recover. He's paged Irina and JC.
Irina here and working w/ him. Haven't yet gotten a hold of JC.
Fri Feb 13 18:30:51
Run 179089
ACTIVATE: PMT Spike Run - Wojtek/Burkard/Vadim
Fri Feb 13 18:38:18
Run 179089
Terminated at 2004.02.13 18:36:55 - RunControl
Fri Feb 13 18:38:19
Run 179089
TERMINATE: PMT Spike Run: avg. L1 rate 58.7, beam status: proton injection started during the run - Wojtek/Burkard/Vadim
Fri Feb 13 18:46:06
Run 179090
ACTIVATE: COSMICS_NOTRACKS [6,392,403] - Wojtek/Burkard/Vadim
Fri Feb 13 18:53:51
Run 179090
TERMINATE: terminate cosmics run - Wojtek/Burkard/Vadim
Fri Feb 13 18:56:21
Run 179091
ACTIVATE: COSMICS_NOTRACKS [6,392,403] again - Wojtek/Burkard/Vadim
Fri Feb 13 19:24:21
Doug called me in for problems rebooting PISABOX. Nikolay
showed me that the program which reads out PMT HVs (C:\pbhvout\pb_hv6.exe) would not start. It would report some
error about LSR_ONOFF tags on VNODE1 and VNODE2, and then exit.
I called Irina in, and then she found the configuration files
(C:\pbhvconf\*) were not there. We found them in pbhvout; maybe
Nikolay accidentally dragged the first folder into the second?
However, we still were getting these same errors after putting
the configuration folder in the correct place. Irina found that
reading out LSR and WHA could be done individually (with "pb_hv6
read wha", for example), but CEM and CHA failed. After
resetting the SY127 CAMAC controller front panels, these worked
also. Finally, the normal readout ("pb_hv6 auto_read") started
up normally.
Still not clear why the complaint is about LSR_ONOFF tags on
VNODE1 and VNODE2. I checked the iFIX databases on PISABOX,
VNODE1, and VNODE2, and this tag appears on none of them.
A clearer error message would have made this go much faster.
Will ask J.C. Yun when I get a chance.
- Steve Hahn
Fri Feb 13 20:05:42
MCR calls. They had trouble w/ a sequencer, which delayed things
a bit. Resolved, so starting shot setup. Expect to begin
loading of final protons in about an hour.
- Doug
Fri Feb 13 20:27:45
 | Prompted by the unexpected erasure of the ADMEM
in one of the CCAL_00 crate and heap corruptions
errors in b0pcal02, we put a memory usage monitor
on crate b0pcal02 for a five day period. No evidence
for a memory leak, per se, but there is some strange
behaviour when the memory usage drops suddently at the
beginning of a SMXQIE calibration (and to a lesser degree,
the QIE ADMEM calibration). See the
Plug e-log
here
for more details |
- W.Badgett
Fri Feb 13 21:09:19
Run 179091
TERMINATE: end test - Wojtek/Burkard/Vadim
Fri Feb 13 21:15:11
Run 179092
ACTIVATE: one more short test run for PULSAR Clist - Wojtek/Burkard/Vadim
Fri Feb 13 21:20:29
Run 179092
TERMINATE: test ended - Wojtek/Burkard/Vadim
Fri Feb 13 21:26:46
Run 179093
ACTIVATE: Another cosmic run - Vadim x2080
Fri Feb 13 21:45:45
MCR message tells us that they're starting to load "final"
protons for store #3231
- doug
-- Fri Feb 13 21:55:21 comment by...doug -- paged rob, kaori, mary and cheng-ju. all are on their way in.
Fri Feb 13 21:56:06
| Date | Time | BLM | Dose |
| 2004.02.13 | 21:52:54 | W Inner BLM | 3.41 | RADS |
| 2004.02.13 | 21:52:54 | W Outer BLM | 2.86 | RADS |
| 2004.02.13 | 21:52:54 | E Inner BLM | 18.48 | RADS |
| 2004.02.13 | 21:52:54 | E Outer BLM | 20.88 | RADS |
Integrated dosage - natasha
Fri Feb 13 21:57:00
Run 179093
TERMINATE: terminating to start the shotsetup run - Vadim x2080
Fri Feb 13 22:08:31
Run 179094
ACTIVATE: AAA_SHOTSETUP PHYSICS_2_01 [4,416,424] - Vadim x2080
Fri Feb 13 22:14:22
Run 179094
TERMINATE: aborted - Vadim x2080
Fri Feb 13 22:21:01
Run 179095
ACTIVATE: AAA_SHOTSETUP PHYSICS_2_01 [4,416,424] - Vadim x2080
Fri Feb 13 22:27:07
Run 179095
TERMINATE: stopping shotsetup to prepare for physics run - Vadim x2080
Fri Feb 13 22:30:45
pbars loaded and TeV at Flattop.
- Doug
Fri Feb 13 22:44:08
Scraping complete.
- protons = 8710E9
- pbars = 1000E9
- Lumi = 50.0E30
waiting for HV ramps to complete.
- doug
Fri Feb 13 22:45:11
Run 179096
Activated at 2004.02.13 22:45:02 - RunControl
Fri Feb 13 22:47:37
Run 179096
ACTIVATE: No Silicon PHYSICS_2_01 [4,416,424]
XFT Test Run , no chage in SL4 gain - Vadim x2080
-- Fri Feb 13 23:10:21 comment by...Cheng-Ju -- Track trigger rates look okay even with the entire XFT SL2
masked on!!!
Fri Feb 13 22:58:51

- natasha
-- Fri Feb 13 22:59:33 comment by...natasha -- Losses and SVRAD during the shot.
Fri Feb 13 23:03:25
Heartbeat box turnd PINK for CEM, CHA, WHA. This seems to mean "Local PC unaccessible". We also had alarms for a moment, but they cleared itself. This is most likely related to problems that PISABOX had earlier today. - natasha
Fri Feb 13 23:08:40
The problem w/ CEM, CHA and WHA cleared itself after some minutes. The expert was called and asked that we have patience with it -- it could take up to 10 minutes for the problem to go away spontaneously. - natasha
Fri Feb 13 23:10:19
Run 179096
Terminated at 2004.02.13 23:10:09 - RunControl
Fri Feb 13 23:12:31
Run 179096
TERMINATE: End of XFT test run#1, COT HV SL1,2 off, no gain change SL4, stereo SL3,5 reduced
gain (~50%), no silicon in this run - Vadim x2080
Fri Feb 13 23:14:24
During the shift some of the boxes on the "Component Status" of the CDF DAQ Monitor keep changing from green to red and back every several seconds. The VxWorks monitor window stays green and everything else looks ok. This "Christmas Tree Lights"-like behaviour is strange. - Vadim
Fri Feb 13 23:15:07
Run 179097
Activated at 2004.02.13 23:14:29 - RunControl
Fri Feb 13 23:15:22
Run 179097
ACTIVATE: PHYSICS_2_01 [4,416,424] , XFT test run, SL4 reduced gain to ~75% - Vadim x2080
Fri Feb 13 23:20:04
 | COT LS2 top-lest graph is empty. |
- S.H. Chang
-- Fri Feb 13 23:34:13 comment by...Cheng-Ju -- Actually the top left graph is not empty (~27000 entries per
bin) . That plot diplays the XFT segment occupancy as a function
of phi for SL2. Since we masked on all the SL2 wires in the XFT
(over 2000 wires), the segment occupancy for SL2 is uniform and
very high.
Fri Feb 13 23:24:46
Run 179096
RUNSTATUS: Marked Bad, explanation:
L1T Tests for XFT w/ COT HV OFF on SL1,2. No silicon in run.
- cdfscico
Fri Feb 13 23:38:56
Run 179097
Terminated at 2004.02.13 23:38:15 - RunControl
Fri Feb 13 23:39:48
Run 179097
TERMINATE: End XFT test run. reduced SL4 gain to ~70%. - Vadim x2080
Fri Feb 13 23:41:41
Run 179098
TERMINATE: end run - Vadim x2080
Fri Feb 13 23:41:42
Run 179098
TERMINATE: End run - Vadim x2080
Fri Feb 13 23:43:50
Run 179099
Activated at 2004.02.13 23:43:08 - RunControl
Fri Feb 13 23:43:51
Run 179099
ACTIVATE: XFT test run, COT SL4 gain reduced to ~50%, XFT SL4 still in 1-miss. - Vadim x2080
Fri Feb 13 23:44:05
Run 179097
RUNSTATUS: Marked Bad, explanation:
L1T tests for xft w/ COT S1,2 OFF and S4 at reduced voltage.
No silicon in run either.
- cdfscico
Fri Feb 13 23:49:15
BMU tripped -- wedge NE 12. - natasha
Fri Feb 13 23:55:19
| Run Number |
Data Type |
Physics Table |
Begin Time |
End Time |
Live Time |
L1 Accepts |
L2 Accepts |
L3 Accepts |
Live Lumi, nb-1 |
GR |
SC |
RC |
|
179096
x2BB98 |
BEAM |
PHYSICS_2_01 [4,416,424] |
22:45:02 |
23:10:09 |
00:22:24 |
21,135,977 |
348,385 |
61,543 |
63.410 |
0 |
1 |
1 |
|
179097
x2BB99 |
BEAM |
PHYSICS_2_01 [4,416,424] |
23:14:29 |
23:38:15 |
00:21:08 |
15,178,169 |
266,124 |
51,387 |
55.746 |
0 |
1 |
1 |
|
179099
x2BB9B |
BEAM |
PHYSICS_2_01 [4,416,424] |
23:43:08 |
|
00:07:35 |
3,428,141 |
64,263 |
13,931 |
16.263 |
|
|
1 |
| Totals |
|
|
|
23:55:03 |
00:51:07 |
39,742,287 |
678,772 |
126,861 |
135.418 |
|
|
|
- End of Shift Report
Sat Feb 14 00:00:18
Run 179099
Terminated at 2004.02.13 23:59:40 - RunControl
Sat Feb 14 00:00:45
Run 179099
TERMINATE: end of test run - Vadim x2080
Sat Feb 14 00:03:38
Shift Summary: * while waiting for shot setup to begin:
- Nikolay found problem w/ slow control software for Pisa
Boxes, Steve Hahn and Irina called-in to fix it
- MCR gave us some quiet time, so did full set of calibs
- myriad set of pulsar test runs
* store 3231 loads final protons at ~22:00
- initial lumi = 50E30
- begin w/ COT/xft test runs
179096 - SL1,2 OFF, SL4 at 100% HV
179097 - SL1,2 OFF, SL4 at 98% HV (70% gain)
179099 - SL1,2 OFF, SL4 at 96% HV (50% gain)
csl notified to flush 179096, when they call back, tell
them about the others.
End of Shift Numbers
|
CDF Run II
Runs 179096, 97, 99
Delivered Luminosity 213
Acquired Luminosity 153
Efficiency 72
|
- doug
Sat Feb 14 00:21:07
Run 179100
Activated at 2004.02.14 00:20:44 - RunControl
Sat Feb 14 00:21:43
Run 179100
ACTIVATE: XFT test run, COT HV in new default setting, XFT SL4 in 3-miss configuration - Vadim x2080